Chiller Plant Optimizer

CLOSED EXPANSION TANK

INSTALLATION AND COMMISSIONING

While installing, ensure that the flow direction as per given arrow marking. Fix a valve at the drain point to facilitate routine maintenance.

 

Modal

Total Height (H)

Leg Height (H)

Diameter (D)

Connection Size (c)

Weight

CET 24

593

280

25

5

CET 50

610

410

25

9

CET 100

899

170

480

25

17

CET 300

1296

150

634

32

45

CET 500

1563

185

740

32

70

CET 750

1736

185

848

50

122

CET 1000

2187

185

848

50

1065

CET 1500

2250

200

958

50

235

CET 2000

2410

300

1112

50

460

CET 3000

2600

300

1316

50

760

CET 4000

2600

300

1520

50

1095

CET 5000

3100

300

1520

50

1300

 

 

Features & Benefits


Prevention of corrosion for air By the contact of piping system and air is completely intercepted, an air (or oxygen) can not be mixed. This prevents the corrosion and extends a piping life far
Excellent air venting capacity By the piping system is maintained at an appropriate positive pressure, the air venting capacity is excellent at piping system
No limitation in establishment place It can be installed every position, so there is no worry about frozen to burst and the space application is convenient Cleans and protects the installation.
Smooth operation capacity By the matter due to mixing of air decreases, efficient operation is possible. (circulating obstacle, pump efficiency decrease, sound arresting, vibrating, make up pump hunting and so on)

Technical Description

Application:

Heating and chilled water systems.

Media:

Non-aggressive and non-toxic system media.

Pressure:

Max. admissible pressure, PN 10 and PN 16

Temperature:

-05C to 70

Material:

MS or SS 304

Membrane:

EPDM

Pre-Charged Pressure:

2 Bar

Thermal Energy Meter

PRESSURIZATION UNIT

Features & Benefits

It ensures positive pressure throughout the system, thus preventing vapor/air locks. wide range of available head keep the system pressurized even if located at the lowest point, like in a plant room or basement
Double Pumps (1 working + Standby), multistage centrifugal pumps quiet, reliable, and rugged.
Micro process-based panel with duty cycling function. excess run time and dry run safety programmed.
RS 485 Modbus Connectivity to connect with building management.
All components i.e. pump pressure transmitter, flow meter, y strainer, ball valve, interconnecting piping and control panel factory mounted on a compact steel frame.

Air and Dirt Separator

Air Separator


The construction is such that all fluid comes into contact with the total adhesion surface of the SS Mesh. Due to the coalescence effect microscopically small gas bubbles in the fluid will adhere to the contact surface of the Mesh, and bubbles will grow into larger bubbles, the larger gas bubbles will have sufficient floating power to be separated via an air chamber. causing more air bubbles to be released than in standard separators.
Dirt Separation
High separation efficiency with SS Mesh technology Cleans your system in fewer cycles, each time reducing dirt particles that would normally deposit in the system with each additional cycle. The dirt collected can be easily and quickly flushed out with the help of the drain valve.
High Efficiency
Separation efficiency increases together with low flow velocity. The pressure drop remains stable regardless of the amount of dirt collected. Suitable for heating and cooling installations.
Clean and protects the installation
Protects critical investments such as boilers, pumps, valves, chillers, and calorie meters, from dirt-related malfunction and failure. No risk of clogging – the dirt collected can be easily and quickly flushed out with the help of the drain valve. Reduces maintenance and associated costs over entire system lifetime.
Application: Hot and Cold-water system

Media: Non-aggressive and non-toxic system media.

Pressure: Max. admissible pressure, PN 16 and PN 20.

Temperature: 0 C to 100C

Material: MS or SS304

Vacuum Degasser

Features & Benefits

• The HIKE Vacuum degasser is a new compact, hydronic system and replaces the conventional large Inline air separator . It keeps the system pressurized and remove the system air. Works on Henry’s law that dissolved gas is proportional to its partial pressure above the liquid. • Large graphical animated touch display. • Easy to schedule degassing program. • Digital display for system pressure, tube pressure, flow rate, degass volume, make volume, • It can work at low pressure (>0.8bar) also. • Smooth working operation with Variable-frequency drive • Modbus RS 485 Connectivity for BMS • It prevents air-lock and cavitation. • Reduces corrosion in piping and sludge formation.

CYCLON DIRT SEPARATOR

INSTALLATION AND COMMISSIONING

While installing, ensure that the flow direction as per given arrow marking. Fix a valve at the drain point to facilitate routine maintenance.

Modal

H

H1

L

Weight

CADS 80

560

320

490

30

CADS 100

875

500

675

75

CADS 125

875

500

675

81

CADS 150

1050

600

675

92

CADS 200

1400

800

900

188

CADS 250

1750

1000

1050

278

CADS 300

2100

1200

1200

435

CADS 350

2450

1400

1406

645

CADS 400

2800

1600

1560

990

Features & Benefits

High separation efficiency with Cyclonic technology Cleans your system in fewer cycles, each time reducing dirt particles that would normally deposit in the system with each additional cycle. The dirt collected can be easily and quickly flushed out with the help of the drain valve. High efficiency independent of dimension Separation efficiency increases together with flow velocity. The pressure drop remains stable regardless of the amount of dirt collected. Even higher protection for higher flows, e.g. in cooling applications. Suitable for heating and cooling installations. Cleans and protects the installation Protects critical investments such as boilers, pumps, valves, chillers, and calorie meters, from dirt-related malfunction and failure. No risk of clogging – the dirt collected can be easily and quickly flushed out with the help of the drain valve. Reduces maintenance and associated costs over entire system lifetime. Air separation Due to the cyclonic effect, pressure in the centre of the device is below system pressure, causing more air bubbles to be released than in standard separators. The air is concentrated in the centre forming larger bubbles, which can raise in the upper section and removed by automatic air vent.

Technical Description

Application:

Heating and chilled water systems.

Media:

Non-aggressive and non-toxic system media.

Pressure:

Max. admissible pressure, PN 16

Temperature:

-4C to 110C

Material:

MS.

Connection:

Flanges according IS 1963

Unpressurized Expansion

Tank Cum Degasser System

The HIKE Pressure maintaining station is a new compact
hydronic system and replaces the conventional large
pressurized expansion tank and air separator. It keeps the
system pressurized within set range and remove the
dissolved gases

Cooling Tower Optimizer

Control Algorithm compares the leaving water temp.
with the ambient wet-bulb temp. and decides the speed
of fan or no. of fans to be operated.
Minimum outlet temperature and cooling tower
approach are to be set for optimization.

BMS System

We keep your buildings automatically cool. They are places for people to live or work. Facilities for learning or healing. Venues for entertainment and shopping. Sites for the specialized storage of tangible goods or mission-critical data. Your buildings have a huge variety of functions; they are central to your mission.
READ MORE

Electronic Pressure Independent valve

It is a high controllability valve with delta t balancing, it
makes the operation pressure independent, save energy
with low differential pressure and high delta t of coil. It
makes system highly efficient and avoid all chances of
low delta t syndrome.

2way Pressure independent CU BTU meter

It is combination of two-way high controllability valve, flow meter and temp sensors, it will balance the flow as per delta t and maintain the return air temperature. It measures the energy rate and energy total

Temp RH and Pressure control system

The simultaneous all-weather program control all the
equipment of AHU i.e. motorized valves, heaters, drive,
humidifiers etc. to maintain the room temperature, RH
and pressure.

Side Stream Filter

Automatic Airvent

Variable Pump Control System